SERIES 4000 12/16V SERVICE MANUAL
12. Operate hydraulic hand pumps and elongate both studs at same time, until nuts of main
bearing caps can be released with the aid of a pin. See Figure 172.
Figure 172
Loosening Nuts at Main Bearing Cap with a Pin
13. Loosen nuts on main bearing cap with a pin (arrow).
14. Relieve tension on studs, and move the dial gages with magnetic holders and hydraulic
preloading devices to the next adjacent main bearing cap.
15. Follow the same procedure to loosen all remaining nuts.
16. Remove loose nuts from studs.
17. Screw eyebolt into bearing cap.
All information subject to change without notice.
Copyright © DETROIT DIESEL CORPORATION
C -243