13-21
Canopen Network
FPMC
Node: 127
Node: 1
Node: 2
Node: 3
Node: 4
20PM
Master
Slave
Slave
Slave
Slave
In A2 mode, there are 6 sets of PDOs for setting servo parameters. The user can monitor servo status
directly by accessing the control registers through CANopen network. Additional setting for PDO parameters
is not required. The PDO allocation for DVP-FPMC (Master) and servo drives (Slaves) is listed as the table
below: 4 sets of PDO for DVP-FPMC and 2 sets of PDO for servo data transmission.
PDO
Master (transmit)
Slave (receive)
1
Target position of profile position mode
(CRn70~CRn71)
Target speed of profile position mode
(CRn72~CRn73)
2
Acceleration time(ms) of profile position mode
(CRn74~CRn75)
Deceleration time(ms) of profile position mode
(CRn76~CRn77)
3
Servo drive control (CRn60)
4
Target position of interpolation position mode
(CRn90~CRn91)
Enable interpolation positioning (CRn92)
5
Servo drive status (CRn20)
Current operating mode of servo drive
(CRn21)
6
Servo drive position (CRn22~ CRn23)
A2 mode communication setting:
z
ASDA-A2 settings
Before setting up CANopen connection, set the servo drives in CANopen mode by the following steps:
1. Set A2 Keypad P1-01as 0x0B
(
Set ASDA-A2 in CANopen mode
)
Summary of Contents for DVP-10PM
Page 1: ......
Page 45: ...2 Hardware Specifications and Wiring DVP PM Application Manual 2 30 MEMO...
Page 125: ...3 Functions of Devices in DVP PM DVP PM Application Manual 3 80 MEMO...
Page 341: ...8 Application Examples DVP PM Application Manual 8 2 Trajectory 3 Trajectory 4...
Page 427: ...9 Electrical CAM DVP PM Application Manual 9 74...
Page 437: ...10 Encrypting User Program DVP PM Application Manual 10 10 MEMO...
Page 458: ...11 G code Application DVP PM Application Manual 11 21 B O100 main program...
Page 561: ...14 Appendix DVP PM Application Manual 14 4 MEMO...