3
Functions of Devices in DVP-PM
DVP-PM Application Manual
3-26
Special
D
Function
10M 20D 20M
OFF
Ø
ON
MANU
Ø
AUTO
AUTO
Ø
MANU
Attrib. Latched Default
Page
number
D1802* Error code of O100
○
○
○
0 - -
R/W
NO
0 3-50
D1803* Error STEP of O100
○
○
○
0 0 -
R/W
NO
0 3-50
D1804* Input terminal polarity 2 (for Z-axis)
╳
╳
○
0 - -
R/W
NO
0 3-48
D1805* Input terminal status 2 (for Z-axis)
╳
╳
○
0 - - R
NO
0 3-49
D1806*
High Byte: Filter coefficient of MPG0 / MPG1
Low Byte: Filter coefficient of other input points other
than X points. Filter frequency: 85000/2N+4(kHz)
○
○
○
0
- -
R/W
NO
0
3-49
D1816* Parameter setting of X axis
○
○
○
-
-
-
R/W YES
0
3-50
D1818 Pulses per revolution (PPR) on X axis (low word)
D1819 Pulses per revolution (PPR) on X axis (high word)
○
○
○
-
-
-
R/W YES
2,000
-
D1820
Displacement per revolution (DPR) of motor on X axis
(low word)
D1821
Displacement per revolution (DPR) of motor on X axis
(high word)
○
○
○
-
-
-
R/W YES
1,000
-
D1822 Maximum speed on X axis: V
MAX
(low word)
D1823 Maximum speed on X axis: V
MAX
(high word)
○
○
○
-
-
-
R/W YES
500K
-
D1824 Bias speed of X axis: V
BIAS
(low word)
D1825 Bias speed of X axis: V
BIAS
(high word)
○
○
○
-
-
-
R/W YES
0
-
D1826 JOG speed of X axis: V
JOG
(low word)
D1827 JOG speed of X axis: V
JOG
(high word)
○
○
○
-
-
-
R/W YES
5,000
-
D1828 Zero return speed of X axis: V
RT
(low word)
D1829 Zero return speed of X axis: V
RT
(high word)
○
○
○
-
-
-
R/W YES
50K
-
D1830
Zero return deceleration speed of X axis: V
CR
(low
word)
D1831
Zero return deceleration speed of X axis: V
CR
(high
word)
○
○
○
-
-
-
R/W YES
1,000
-
Number of Zero point signals (PG0) on X axis:N
○
○
○
- - -
R/W
YES
0 3-51
D1832*
Times of acyclic CAM repetitions
╳
○
○
- - -
R/W
YES
0 -
Number of pulses for zero return on X axis: P
○
○
○
- - -
R/W
YES
0 3-51
D1833*
Distribution of remaining acyclic CAM pulses
╳
○
○
- - -
R/W
YES
0 -
Definition of zero point on X axis: HP (low word)
○ ○ ○
- - -
R/W
YES
0 3-51
D1834
Pulses for delay start of acyclic CAM
╳
○
○
- - -
R/W
YES
0 -
Definition of zero point on X axis: HP (high word)
○ ○ ○
- - -
R/W
YES
0 -
D1835
Pulses for delay start of CAM
╳
○
○
- - -
R/W
YES
0 -
D1836 Acceleration time of X axis: T
ACC
○
○
○
- - -
R/W
YES
500
-
D1837 Deceleration time of X axis: T
DEC
○
○
○
- - -
R/W
YES
500
-
Target position (I) of X axis: P(I) (low word)
○
○
○
○
- -
R/W
NO
0 -
D1838
Lower bound of CAM synchronized output (low word)
╳
○
○
○
-
- -
R/W
NO
0 -
Summary of Contents for DVP-10PM
Page 1: ......
Page 45: ...2 Hardware Specifications and Wiring DVP PM Application Manual 2 30 MEMO...
Page 125: ...3 Functions of Devices in DVP PM DVP PM Application Manual 3 80 MEMO...
Page 341: ...8 Application Examples DVP PM Application Manual 8 2 Trajectory 3 Trajectory 4...
Page 427: ...9 Electrical CAM DVP PM Application Manual 9 74...
Page 437: ...10 Encrypting User Program DVP PM Application Manual 10 10 MEMO...
Page 458: ...11 G code Application DVP PM Application Manual 11 21 B O100 main program...
Page 561: ...14 Appendix DVP PM Application Manual 14 4 MEMO...