9
Electrical CAM
DVP-PM Application Manual
9-40
500
0
-500
0 100 200 300 400 500 600 700 800 900 1,000
500
D
isp
la
ce
m
e
n
t
Degree
Length of S lave:
Degree
1
0
-1
0 100 200 300 400 500 600 700 800 900 1,000
Length of sync area of Slave:
300
Length of Master:
1,000
Magnification of Slave:
F1.0
Ve
lo
cit
y
Parameters
SV
Length of Master
1000
Length of Slave
500
Length of sync area
200
Magnification ratio
1.0
Max magnification
ratio
10.0
Acceleration curve
0
CAM curve
0
CAM curve setting
Only single
data
real-time
modification
is applicable
Results 0
Control Steps:
Step 1: Add 2 sets of E-CAM charts and set the resolution as 300.
Step 2: Download the below program in DVP-20PM and execute.
Step 3: Set M1 to write the parameters for rotary cut E-CAM into D100~D112 and CR#10000 into D0
Step 4: Set M0 to write the data in D100~D112 into special register CR#10000 to generate the rotary cut
E-CAM curve.
Step 5: Stop the DVP-PM and upload the program.
Step 6: Monitor the uploaded E-CAM Chart-0, which is the generated rotary cut E-CAM curves.
Ladder Diagram:
Summary of Contents for DVP-10PM
Page 1: ......
Page 45: ...2 Hardware Specifications and Wiring DVP PM Application Manual 2 30 MEMO...
Page 125: ...3 Functions of Devices in DVP PM DVP PM Application Manual 3 80 MEMO...
Page 341: ...8 Application Examples DVP PM Application Manual 8 2 Trajectory 3 Trajectory 4...
Page 427: ...9 Electrical CAM DVP PM Application Manual 9 74...
Page 437: ...10 Encrypting User Program DVP PM Application Manual 10 10 MEMO...
Page 458: ...11 G code Application DVP PM Application Manual 11 21 B O100 main program...
Page 561: ...14 Appendix DVP PM Application Manual 14 4 MEMO...