11
G-code Application
DVP-PM Application Manual
11-15
to D65 will change the recipe group number.
Design instructions in DVP-PM00M:
DTO/DFROM instructions are used for downloading G-codes. The applied instructions are listed as below:
Initialization:
X0
TO
K255
K0
K0
K1
File conversion
X0
TO
K255
K0
D3000
K1
Check the completed conversion results
X0
TO
K255
K1
K0
K1
The below example explains the instructions for receiving G-codes. Specify length of recipe with 50 words
and groups of recipe with 10. Execute file conversion and check the conversion results. If the conversion
results are correct, the downloaded file will be stored in D3002~D3501. If errors occur, 0xffff will be recorded
in D3000, and the number of error group (row) will be displayed in D3001. After uploading the program to
PMSoft, you can check OX0 motion subroutine for the received G-codes.
Step 1: Move K1 to D66 to designate the recipe group number. Initialize the file conversion process and
setting the format of recipe according to the recipe setup in Screen Editor.
Summary of Contents for DVP-10PM
Page 1: ......
Page 45: ...2 Hardware Specifications and Wiring DVP PM Application Manual 2 30 MEMO...
Page 125: ...3 Functions of Devices in DVP PM DVP PM Application Manual 3 80 MEMO...
Page 341: ...8 Application Examples DVP PM Application Manual 8 2 Trajectory 3 Trajectory 4...
Page 427: ...9 Electrical CAM DVP PM Application Manual 9 74...
Page 437: ...10 Encrypting User Program DVP PM Application Manual 10 10 MEMO...
Page 458: ...11 G code Application DVP PM Application Manual 11 21 B O100 main program...