9
Electrical CAM
DVP-PM Application Manual
9-21
Original path:
Path when M1757 = ON:
M1757 = ON
Left/right Limit
Master position
Slave speed
9.4 Set up E-CAM Data
9.4.1 Use PMsoft CAM Chart to Set up E-CAM Data
The relatonionship defined by users between Master and Slave is called E-CAM Data.
For describing E-CAM Data there are 2 methods:
Method 1: Point-to-point relationship on X and Y axes.
Method 2: Function, e.g. Y = f(X)
To obtain E-CAM data there are also 2 methods:
Method 1: Obtain E-CAM Data according to the measured point-to-point values.
Method 2: Obtain E-CAM Data according to the E-CAM Data function
E-CAM Data can be used to describe various CAM curves. After the relationship between Master and Slave is
confirmed, we can obtain Slave position according to the Master position. For example, the below disgram
illustrates an E-CAM Data of SIN wave.
400
200
0
-200
-400
50
100
150
200
250
300
350
400
0
In PMSoft, E-CAM Data is represented as CAM Chart. You can add CAM Chart or delete CAM Chart by
right-clicking at CAM Chart in System Information column.
Summary of Contents for DVP-10PM
Page 1: ......
Page 45: ...2 Hardware Specifications and Wiring DVP PM Application Manual 2 30 MEMO...
Page 125: ...3 Functions of Devices in DVP PM DVP PM Application Manual 3 80 MEMO...
Page 341: ...8 Application Examples DVP PM Application Manual 8 2 Trajectory 3 Trajectory 4...
Page 427: ...9 Electrical CAM DVP PM Application Manual 9 74...
Page 437: ...10 Encrypting User Program DVP PM Application Manual 10 10 MEMO...
Page 458: ...11 G code Application DVP PM Application Manual 11 21 B O100 main program...
Page 561: ...14 Appendix DVP PM Application Manual 14 4 MEMO...