About Your System
71
HyperTransport
error caused a
system reset.
Please check the
system event log
for details.
HyperTransport
error.
See "Getting Help" on
page 217.
Invalid
flexAddress for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only
Keyboard
controller
failure.
Faulty keyboard controller
(faulty blade board).
See "Getting Help" on
page 217.
Keyboard failure.
Loose or improperly
connected keyboard cable
Ensure that the keyboard is
properly connected. If the
problem persists, replace the
keyboard.
Manufacturing mode
detected.
System is incorrectly
configured.
Set the NVRAM_CLR
jumper to "on" and reboot
the blade. See
Figure 7-4 for the jumper
location.
Table 1-18.
Blade Messages
(continued)
Message
Causes
Corrective Actions