About Your System
51
Half-Height Blades (PowerEdge M600 and M605)
For a half-height blade in bay
n
:
•
The integrated NIC will connect to I/O module A1, port
n
and I/O module
A2, port
n.
•
Mezzanine card B will connect to I/O module B1, port
n
and I/O module
B2, port
n.
•
Mezzanine card C will connect to I/O module C1, port
n
and I/O module
C2, port
n.
For example, in a blade in slot 12, the integrated NIC will connect to
I/O
module A1, port
12 and I/O module A2, port 12.
Figure 1-17 shows the port connections for a half-height blade in bay 1 with
two mezzanine cards.
Table 1-13.
Example of I/O Module Port Assignments - Half-Height Blade 1
Blade 1
I/O Module
A1
B1
C1
C2 B2
A2
Integrated LOM Port 1
Port 11
Mezzanine
Card C
Port 1
Port 1
Mezzanine
Card B
Port 1
Port 1
Summary of Contents for PowerEdge M600