74
About Your System
Read fault.
Faulty diskette, diskette
drive, or optical drive.
Replace the diskette. Ensure
that the drive cable is
properly connected. See
"Troubleshooting USB
Devices" on page 183 or
"Troubleshooting Hard
Drives" on page 192 for the
appropriate drive(s)
installed in your system.
Remote
Configuration
update attempt
failed.
Blade could not
implement Remote
Configuration request.
Retry Remote
Configuration.
Sector not found.
Seek error.
Seek operation
failed.
Faulty diskette or hard
drive.
Replace the diskette. If the
problem persists, see
"Troubleshooting Hard
Drives" on page 192 for the
appropriate drive installed in
your system.
Shutdown failure.
Shutdown test failure.
Ensure that all memory
modules are properly
installed. See
"Troubleshooting Blade
Memory" on page 191. If the
problem persists, see
"Getting Help" on page 217.
Spare bank
enabled.
Memory sparing enabled.
Information only.
The amount of
system memory has
changed.
Faulty memory module.
See "Troubleshooting Blade
Memory" on page 191. If the
problem persists, see
"Getting Help" on page 217.
Information only, if you
have changed the memory
configuration.
Table 1-18.
Blade Messages
(continued)
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge M600
Page 10: ...10 Contents 8 Getting Help 217 Contacting Dell 217 Glossary 219 Index 231 ...
Page 50: ...50 About Your System Figure 1 16 Example of Full Height Blade Port Mapping Blade 3 ...
Page 52: ...52 About Your System Figure 1 17 Example of Half Height Blade Port Mapping ...
Page 156: ...156 Installing Blade Components ...
Page 178: ...178 Installing Enclosure Components ...
Page 202: ...202 Running System Diagnostics ...
Page 216: ...216 System Board Information ...
Page 218: ...218 Getting Help ...
Page 236: ...236 Index ...