Installing Blade Components
109
Figure 3-8.
Memory Locations - PowerEdge M805
General Memory Module Installation Guidelines - PowerEdge M805
To ensure optimal performance of your system, observe the following
guidelines when installing your system memory.
•
Memory modules must be installed in pairs of identically-sized DIMMs,
beginning with slots A1 and A2 (processor 1) and B1 and B2. These slots
are marked by white ejector tabs.
•
All memory modules in the blade must be identical in speed and
technology. The memory modules in each pair must be the same size.
B1
B8
A8
A1
Summary of Contents for PowerEdge M600