MCO 305 Design Guide
__ PC Software Interface __
66
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
NB!:
Remember the following when you delete the EEPROM:
1. Check whether you have saved all the necessary programs on the computer so that you can
load these into the FC 300 again once the EEPROM has been deleted.
2. Check whether you have saved the parameters for all the FC 300s connected in a file on the computer.
3. Click on
Memory
o
Delete EEPROM
.
4. Re-load the parameters and the necessary programs in the controller or controllers.
Memory > Save Part in LCP EEPROM
Use the corresponding function to save
o
User Parameters
,
o
Arrays
,
o
All Application Data
(contain
additional to user parameters and arrays the application programs), or
o
Option Parameters
(MCO 305
parameters) individually in the EEPROM of the LCP.
Controller > Reset Parameters, Arrays, or Complete
With
Reset
o
Parameters
all global parameters and
all axis parameters in the MCO are reset to the
factory settings.
With
Reset
o
Arrays
you can delete all array defini-
tions in the RAM without deleting the parameters
etc. This command has the same effect as the
command DELETE ARRAYS.
NB!:
If you then carry out SAVE ARRAYS, the arrays in the EEPROM are also overwritten!
With
Reset
o
Complete
not only all parameters, but also the programs and arrays are erased and
the MCO 305 is reset to the basic default setting . . .
NB!:
. . .
and this happens immediately – not only after the controller has been turned on and off as is
the case when you delete EEPROM.