MCO 305 Design Guide
__ Software Reference __
140
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
OUTAN
Summary
Sets speed reference.
Syntax
OUTAN
v
Parameter
v = bus reference
range: –0X4000 – 0X4000 = –100 % – 100 %
Description
The OUTAN command can set FC 300 bus reference (speed or torque reference
depending on setting of FC 300 par. 1-00).
With OUTAN it is also possible to turn off the controller in OPEN LOOP using MOTOR
OFF and to operate the FC 300 without feedback as a pure frequency converter. In
this manner you can use APOSS to directly output set values, to read inputs, etc.
NB!:
The command MOTOR OFF must be executed previously. Thus, monitoring of the
position error is no longer active.
Command Group
I/O
Cross Index
MOTOR
OFF,
MCO 305 Operating Instructions, FC 300 Design Guide
Syntax Example
MOTOR OFF
/* turn off controller */
OUTAN 0X2000
/* set speed reference 50% */
OUTB
Summary
Alteration of the condition of a digital output byte
Syntax
OUTB n v
Parameter
n = output byte
0 = 1 – 8
1 = 27,29
v = value (0 . . . 255)
Description
With the OUTB command the condition of the digital outputs can be changed byte-
by-byte. The byte value transferred determines the condition of the individual
outputs. The bit with the lowest value in the byte corresponds to the set condition
of output 1.
NB!:
After switching on the system, all outputs are OFF. Outputs which have pre-defined
functions according to the I/O parameter settings will also be influenced by the
OUTB command! The actual output status remains as it is even after program end
or program aborted.
Output circuit and maximum load current see MCO Operating Instructions.
Command Group
I/O
Cross Index
OUT, IN, INB,
Parameters: 33-63...70
Terminal X59/n Digital Output
, O_FUNCTION_n
Syntax Examples
OUTB 0 10
// switch through outputs 2 and 4, disable other outputs
OUTB 0 245
// disable outputs 2 and 4, switch through all other outputs
OUTB 0 128
// switch through output 8 only, disable others
Program Sample
OUTB_01.M
Summary of Contents for MCO 305