MCO 305 Design Guide
__ Software Reference __
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
127
MOVESYNCORIGIN
Summary
Relative shifting of the origin of synchronization
Syntax
MOVESYNCORIGIN
mvalue
Parameter
mvalue =
Relative offset in relation to the Master in qc
Value range:
(–MLONG / par. 33-11 SYNCFACTS) – (MLONG / par. 33-11 SYNCFACTS)
Description
The command shifts the origin of synchronization in relation to the master. While
SET SYNCPOSOFFS sets the offset position absolutely, MOVESYNCORIGIN always
relates to the last one and shifts the offset position relatively. If you have to shift
the offset position continually, you can prevent too large numbers or an overflow in
this way.
NB!:
Valid for position synchronization SYNCP and position synchronization with marker
correction SYNCM.
Command Group
SYN
Cross Index
SET,
Parameters: 33-11
Synchronization Factor Slave,
SYNCFACTS
33-12
Position Offset for Synchronization,
SYNCPOSOFFS
Syntax Example
MOVESYNCORIGIN 1000