MCO 305 Design Guide
__ Parameter Reference __
¾
default setting
[ ]
value for use in communication via serial communication port
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
215
MCO Basics Settings, Parameter List
Par. No.
#
Parameter name
Parameter description
Default
setting
Changes
during
operation
4-set-up
Conver-
sion index
Type
32-0*
Encoder 2 - Slave
32-00
ENCODERTYPE
Incremental Signal Type
[1] RS422
'TRUE'
1 set-up
Uint8
32-01
ENCODER
Incremental Resolution
1024 PPR
TRUE
1 set-up
Uint32
32-02
ENCODER ABSTYPE
Absolute Protocol
[0] None
TRUE
1 set-up
Uint8
32-03
ENCODER ABSRES
Absolute Resolution
8192 PPR
TRUE
1 set-up
Uint32
32-05
ENCODER ABSTYPE
Absolute Encoder Data
Length
25 Bit
TRUE
1 set-up
Uint8
32-06
ENCODERFREQ
Absolute Encoder Clock
Frequency
262.000 kHz
TRUE
1 set-up
Uint32
32-07
ENCODER CLOCK
Absolute Encoder Clock
Generation
[1] On
TRUE
1 set-up
Uint8
32-08
ENCODER DELAY
Absolute Encoder Cable
Length
0
TRUE
1 set-up
Uint16
32-09 ENCODER
MONITORING
Encoder Monitoring
[0] Off
TRUE
1 set-up
Uint8
32-10
POSDRCT
Rotational Direction
[1] No action
TRUE
1 set-up
Uint8
32-11
POSFACT_N
User Unit Denominator 1
TRUE
1
set-up
Uint32
32-12
POSFACT_Z
User Unit Numerator
1
TRUE
1 set-up
Uint32
32-3*
Encoder 1 - Master
32-30
MENCODER TYPE
Incremental Signal Type
[1] RS422
TRUE
1 set-up
Uint8
32-31
MENCODER
Incremental Resolution
1024 PPR
TRUE
1 set-up
Uint32
32-32 MENCODER
ABSTYPE Absolute
Protocol
[0] None
TRUE
1 set-up
Uint8
32-33
MENCODER ABSRES
Absolute Resolution
8192 PPR
TRUE
1 set-up
Uint32
32-35
MENCODER DATLEN
Absolute Encoder Data
Length
25 Bit
TRUE
1 set-up
Uint8
32-36
MENCODER FREQ
Absolute Encoder Clock
Frequency
262.000 kHz
TRUE
1 set-up
Uint32
32-37 MENCODER
CLOCK Absolute
Encoder
Clock
Generation
[1] On
TRUE
1 set-up
Uint8
32-38
MENCODER DELAY
Absolute Encoder Cable
Length
0
TRUE
1 set-up
Uint16
32-39 MENCODER
MONITORING
Encoder Monitoring
[0] Off
TRUE
1 set-up
Uint8
32-40
MENCODER TERM
Encoder Termination
[1] On
TRUE
1 set-up
Uint8
32-5*
Feedback Source
32-50
Source Slave
[2] Enc2
TRUE
1-set-up
32-6*
PID-Controller
32-60 KPROP
Proportional
Factor 30
TRUE
1
set-up
0
Uint32
32-61
KDER
Derivative Value for PID
Control
0
TRUE
1 set-up
0
Uint32
Summary of Contents for MCO 305
Page 4: ......