MCO 305 Design Guide
__ Parameter Reference __
¾
default setting
[ ]
value for use in communication via serial communication port
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
209
Brake control no [5]:
Defines digital output_n
for brake. If an output is defined for the brake,
this remains active even when the program is
terminated with ESC.
The output is activated (24 V) in the case of an
abort or option error if par. 33-83 ERRCOND is
set to [1] or [3].
NB!:
The brake output must always be reset by
an OUT command in the program.
Example
ON ERROR GOSUB err_handle
// p. 33-66 O4 is set to [6]
SET ERRCOND 1
// Main program loop
SUBPROG err_handle
WAITI
1
ERRCLR
OUT 4 1
RETURN
Brake control nc [6]:
Defines digital output_n
for brake. If an output is defined for the brake,
this remains active even when the program is
terminated with ESC.
The output is activated (0 V) in the case of an
abort or option error if par. 33-83 ERRCOND is
set to [1] or [3].
NB!:
The brake output must always be re-set
by an OUT command in the program.
33-63 Terminal X59/1 Digital Output
O_FUNCTION_1
¾
No function
[0]
Function
Defines function of digital output 1 of MCO 305.
NOTE: This parameter is only visible when par. 33-
60 IOMODE = 1, i.e. output 1 is not used in
standard mode.
33-64 Terminal X59/2 Digital Output
O_FUNCTION_2
¾
No function
[0]
Function
Defines function of digital output 2 of MCO 305.
NOTE: This parameter is only visible when par. 33-
60 = 1, i.e. output 2 is not used in standard mode.
33-65 Terminal X59/3 Digital Output
O_FUNCTION_3
¾
No function
[0]
Function
Defines function of digital output 3 of MCO 305.
33-66 Terminal X59/4 Digital Output
O_FUNCTION_4
¾
No function
[0]
Function
Defines function of digital output 4 of MCO 305.
33-67 Terminal X59/5 Digital Output
O_FUNCTION_5
¾
No function
[0]
Function
Defines function of digital output 5 of MCO 305.
33-68 Terminal X59/6 Digital Output
O_FUNCTION_6
¾
No function
[0]
Function
Defines function of digital output 6 of MCO 305.
33-69 Terminal X59/7 Digital Output
O_FUNCTION_7
¾
No function
[0]
Function
Defines function of digital output 7 of MCO 305.
33-70 Terminal X59/8 Digital Output
O_FUNCTION_8
¾
No function
[0]
Function
Defines function of digital output 8 of MCO 305.
Summary of Contents for MCO 305
Page 4: ......