MCO 305 Design Guide
__ Parameter Reference __
¾
default setting
[ ]
value for use in communication via serial communication port
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
213
34-7* Diagnosis Readouts
Parameters for readout of MCO alarms.
34-70 MCO Alarm Word 1
Function
Displays MCO 305 alarm word for readout of MCO
errors in MCT 10.
Par. 34-70 cannot be readout while motor is
running.
Bit
Hex
Dec
Meaning
0
00000001
1
FC not enabled
1
00000002
2
Error not reset
2
00000004
4
HOME not done
3
00000008
8
Position error
4
00000010
16
Index not found
5
00000020
32
Hardware end limit
exceeded
6 00000040
64
Software
end
limit
exceeded
7
00000080
128
No external 24 V
8 00000100
256
Digial
output
overload
9
00000200
512
Encoder error
10 00000400
1024
Memory
error
11
00000800
2048
Parameter memory
corrupted
12 00001000
4096
Program
memory
corrupted
13
00002000
8192
Reset by CPU
14 00004000
16384
WAITNDX
timeout
15
00008000
32768
Internal MCO fault
16
00010000
65536
Home vel zero
..
..
..
not used
31
80000000
2147483648
MCO alarm word 2
34-71 MCO Alarm Word 2
Function
Displays MCO 305 alarm word for readout of MCO
errors in MCT 10.
Par. 34-71 cannot be readout while motor is
running.
Bit
Hex
Dec
Meaning
0 00000001
1
Illegal
axis
number
1
00000002
2
Unknown command
2 00000004
4
Unknown
parameter
3
00000008
8
Too many loops
4 00000010
16 Too
many
interrupts
5
00000020
32
Too many GOSUB
6 00000040
64 Too
many
RETURN
7
00000080
128
Use abort
8 00000100
256 LINK
failed
9
00000200
512
Wrong array size (DIM)
10
00000400
1024
Array too small
11
00000800
2048
Too many time
interrupts
12
00001000
4096
Out of memory
13
00002000
8192
Memory locked
14 00004000
16384 Illegal
cam
array
15
00008000
32768
Parameter save failed
.