MCO 305 Design Guide
__ Parameter Reference __
¾
default setting
[ ]
value for use in communication via serial communication port
216
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
Par. No.
#
Parameter name
Parameter description
Default
setting
Changes
during
operation
4-set-up
Conver-
sion index
Type
32-62 KINT
Integral
Factor
0 TRUE
1
set-up
0
Uint32
32-63
KILIM
Limit Value for Integral Sum
1000
TRUE
1 set-up
0
Uint16
32-64 BANDWIDTH
PID
Bandwidth
1000
TRUE
1
set-up
0
Uint16
32-65
FFVEL
Velocity Feed-forward
0
TRUE
1 set-up
0
Uint32
32-66 FFACC
Acceleration
Feed-forward
0 %
TRUE
1 set-up
0
Uint32
32-67
POSERR
Maximum Tolerated Position
Error
20000 qc
TRUE
1 set-up
Uint32
32-68
REVERS
Reverse Behavior for Slave [0]
Reversing
TRUE
1
set-up
Uint8
32-69
TIMER
Sampling Time for PID
control
1 ms
TRUE
1 set-up
Uint16
32-70
PROFTIME
Scan Time for Profile
Generator
[1] 1 ms
TRUE
1 set-up
Uint8
32-71
REGWINMAX
Size of the Control Window
(Activation)
0 qc
TRUE
1 set-up
Uint32
32-72
REGWINMIN
Size of the Control Window
(Deactivation)
0 qc
TRUE
1 set-up
Uint32
32-8*
Velocity & Acceleration
32-80 VELMAX
Maximum Velocity
(Encoder)
1500 RPM
TRUE
1 set-up
Uint32
32-81
RAMPMIN
Shortest Ramp
1 s
TRUE
1 set-up
Uint32
32-82
RAMPTYPE
Ramp Type
0
TRUE
1 set-up
Uint8
32-83
VELRES
Velocity Resolution
100
TRUE
1 set-up
Uint16
32-84
DFLTVEL
Default Velocity
50
TRUE
1 set-up
Uint16
32-85
DFLTACC
Default Acceleration
50
TRUE
1 set-up
Uint16