MCO 305 Design Guide
__ Troubleshooting __
222
MG.33.L4.02 – VLT
®
is a registered Danfoss trademark
Error
no.
Error text
Description
149
Too many inter.
Too many interrupt functions.
150
No ext. 24V
External supply is missing.
151
Too many gosub
Too many nested GOSUB commands
152
Too many return
Too many RETURN commands.
154
D. out overload
Digital Output overloaded.
155
LINK failed
LINKGPAR command failed.
162
Memory error
Error in verifying; EEPROM: address % defect.
170
Array size (DIM)
Error in DIM command.
171
Array too small
Attempt was made to cross array bounds.
179
Waitndx
timeout
Timeout
while waiting for index.
184
Too many ontime
Too many time interrupts.
187
Out of memory
No more room for variables.
190
Memory locked
The program memory is write-protected.
191
Illegal cam array
Curve array wrong.
192
Encoder error
Encoder error
199
Internal MCO fault
Internal MCO fault
Error 103
Illegal axis num.
An attempt has been made to find an axis which
does not exist in the controller.
Check to see if the program axis command has an
invalid number or a general axis command
(...X(*)).
Error 105
Error not reset
An attempt has been made to execute a motion
command, although a momentary error message
has not been cleared.
Error 106
Home not done
Failed to move to HOME position. According to the
axis par. 33-00
Force HOME
, a forced move to the
machine zero-point is demanded, before other
motion commands can be executed. This move to
the machine zero-point has not been executed.
Error 107
Home vel. zero
An attempt was made to execute the HOME
command but the motor is set to 0 in par. 33-03
Velocity of Home Motion
.
Error 108
Position error
The distance between the set and the real position
was greater than the
Maximum Tolerated Position
Error
defined in par. 32-67.
Causes:
Mechanically blocked or overloaded drive,
par. 32-67
Max. Tolerated Position Error
too
small,
commanded speed greater than FC 300 para-
meters 4-13
Motor Speed High Limit
and 3-03
Maximum Reference
,
commanded acceleration too great,
par. 32-60
Proportional Factor
too small, or
FC 300 not enabled.