![background image](http://html.mh-extra.com/html/daikin/altherma/altherma_service-manual_501166227.webp)
3
|
Components
Service manual
227
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a
b
c
d
d
e
c
a
DC fan motor connector X108A
b
DC fan motor harness
c
Tie strap (left side of PCB)
d
Tie strap (on stop valve fixation plate)
e
Ferrite core
3
On the left side of the main PCB, cut the tie straps that fix the DC fan motor
harness.
4
Cut the 2 tie straps that fix the DC fan motor harness to the stop valves
fixation plate.
5
Unlock the ferrite core to remove the DC fan motor harness from the core.
6
If applicable; cut the tie strap(s) that tie up the excessive DC fan motor
harness.
7
Slightly bend the harness retainers to detach the DC fan motor harness.
a
b
b
c
b
e
d
d
a
DC fan motor harness
b
Harness retainer
c
Opening in partition plate
d
Screw
e
DC fan motor assy
8
Guide the DC fan motor harness though the opening in the partition plate.