3
|
Components
Service manual
129
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
3.5 Booster heater
3.5.1 Checking procedures
INFORMATION
It is recommended to perform the checks in the listed order.
To perform a resistance check of the booster heater
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Check that the booster heater thermal protector functions correctly.
"3.6 Booster heater thermal protector"
1
Remove the required plate work, see
a
a
Booster heater contactor K3M
2
Measure the booster heater resistance between K3M/1 and K3M/3.
Result:
The measured resistance MUST be approximately 18 Ω.
INFORMATION
314] for more detailed information.
INFORMATION
Make sure that the wiring between the booster heater contactor and the booster
heater is properly connected and NOT damaged (check continuity), see
Is the measured booster heater
resistance correct?
Action
Yes
Return to
129] of the booster
heater and continue with the next
procedure.
No
Replace the booster heater, see
Summary of Contents for ALTHERMA