![background image](http://html.mh-extra.com/html/daikin/altherma/altherma_service-manual_501166210.webp)
3
|
Components
Service manual
210
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a
c
d
b
a
Fuse F1U
b
Fuse F3U
c
Fuse F4U
d
Fuse F5U
For fuses F4U and F5U
Blown fuse on the noise filter PCB?
Action
Yes
Replace the noise filter PCB, see
No
PCB and continue with the next
procedure.
For fuses F1U and F3U
Blown fuse on the noise filter PCB?
Action
Yes
No
PCB and continue with the next
procedure.
Problem solved?
After all checking procedures listed above have been performed:
Is the problem solved?
Action
Yes
No further actions required.