![background image](http://html.mh-extra.com/html/daikin/altherma/altherma_service-manual_501166141.webp)
3
|
Components
Service manual
141
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
b
a
a
c
a
Strip
b
Compressor insulation
c
Compressor
2
Route the compressor thermal protector and crankcase heater wiring out of
the compressor insulation.
3
Attach the strips.
INFORMATION
Make sure that the insulation nicely fits around the compressor.
To remove the compressor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
Prerequisite:
Remove the compressor insulation.
Prerequisite:
Recuperate the refrigerant from the refrigerant circuit, see
1
If needed, remove any parts to create more space for the removal of the
compressor.
DANGER: RISK OF ELECTROCUTION
Confirm the rectifier voltage is below 10 V DC before proceeding, see
2
Remove the cover of the compressor wire terminals.