![background image](http://html.mh-extra.com/html/daikin/altherma/altherma_service-manual_501166127.webp)
3
|
Components
Service manual
127
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a
b
a
Backup heater thermal protector sensor
b
Backup heater
4
Loosen and remove the 2 screws that fix the backup heater thermal protector
bracket to the switch box.
b
c
a
a
c
d
a
Screw
b
Backup heater thermal protector bracket
c
Screw
d
Backup heater thermal protector
5
Loosen and remove the 2 screws that fix the backup heater thermal protector
to the bracket.
6
Disconnect the wires from the backup heater thermal protector terminals.
7
Remove the backup heater thermal protector and sensor from the unit.
8
To install the backup heater thermal protector, see
126].
To install the backup heater thermal protector
1
Route the backup heater thermal protector sensor and wiring through the
grommet of the switch box.
2
Insert the backup heater thermal protector sensor in the backup heater.
Summary of Contents for ALTHERMA