Summary of Contents for KSIA009-H216-I

Page 1: ...read this owner s manual carefully and thoroughly before operating the unit Take care of this manual for future reference KSIA SERIES SPLIT TYPE ROOM AIR CONDITIONER For Split Wall Mounted Series R410a Inverter Model Type For F KSIA009 H216 I KSIA009 H216 O KSIA012 H216 I KSIA012 H216 O KSIA018 H216 I KSIA018 H216 O KSIA024 H216 I KSIA024 H216 O ...

Page 2: ...or or DC motor feedback fault 5 E5 Indoor outdoor communication fault 6 F0 Outdoor DC Fan motor fault 7 F1 IPM modular fault 8 F2 PFC modular fault 9 F3 Compressor operationfault 10 F4 Exhaust Temperature sensor fault 11 F5 Compressor top cover protection 12 F6 Outdoor ambient temp sensor fault 13 F7 Over under voltage protection 14 F8 Outdoor modular communication fault 15 F9 Outdoor E PROM fault...

Page 3: ...nit and outdoor unit to see if it is properly connected The connecting must be done according to the wiring diagram please also notice that even different models may have the connecting cord of the same specification Please check if the marks at the connecting terminal and the marks on the cord can match otherwise the air conditioner will not work normally If the following phenomena are found the ...

Page 4: ...stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature If you turn off the air conditioner and restart it immediately it will return to normal in 3 minutes after that the air conditioner will automatically adjust the indoor fan speed to what you set 3 The compressor works discontinuously at dehumidifying mode The air ...

Page 5: ...o Power Display Items a Check if the input voltage is correct b Check if the AC power supply connecting is correct c Check if the output voltage of the manostat L7805 IC2 is correct Trouble shooting procedure ...

Page 6: ... Items a Check if the indoor fan motor is connected correctly to the connector CN8 b Check if the AC input voltage is correct c Check if the IC of indoor fan motor is connected correctly to the connector CN2 d Check if the capacity of indoor fan motor is connected correctly to the ...

Page 7: ...15 4 The Outdoor Unit Does Not Work Items a Check if the input voltage is correct b Check if the wire connection of the outdoor connecting terminal is correct Trouble shooting procedure ...

Page 8: ...16 5 The Step Motor Does Not Work Items a Check if the input voltage is correct b Check if the step motor controlling the up down movement firmly connected to Cn2 Trouble shooting procedure ...

Page 9: ...17 6 Heating Mode Can Work But No Hot Air Blow Check if the set temperature is lower than the indoor temperature Check if the indoor PCB is connected to the terminal correctly ...

Page 10: ...18 7 Remote Control Can Not Work Trouble shooting rocedure ...

Page 11: ...e l a re lo o a re ere ra e ar o l a re Pro c c o r 201 l a re Pro c c 2190 NW 89 Place Doral FL 33172 USA Tel 305 593 8358 www klimaire com Fax 305 675 2212 sales klimaire com ...