CyberOptics Corporation
45
Connecting SMEMA Cables
Connecting SMEMA Cables
Use the SMEMA connections to facilitate board handling between machines in the SMT line.
➢
To connect SMEMA cables
1. Shut down Windows and then push the E-Stop button on the front of the unit.
2. Turn off all electrical power to the system. For more information, refer to “
Figure 41.
SMEMA Connectors
3. Route the SMEMA cables under the SE505 unit to the connectors on the rear.
4. Connect the upstream cable to the upper connector.
5. Connect the downstream cable to the lower connector.
Downstream
SMEMA connector
Upstream
SMEMA connector
Pins
Upstream Cable
Downstream Cable
1 - 2
Machine Ready
-
3 - 4
Board Available
Board Available
7 - 8
Failed Board Available
Failed Board Available
1
3
7
4
11
8
14
12
Connector Pinout
2
Back Electrical
Panel
Summary of Contents for SE505
Page 1: ...SE505 Hardware Manual ...
Page 6: ...Contents vi SE505 Hardware Manual ...
Page 10: ...x SE505 Hardware Manual ...
Page 72: ...Chapter 3 Installation 62 SE505 Hardware Manual ...
Page 168: ...Chapter 4 Replacing Components and Preventive Maintenance 158 SE505 Hardware Manual ...
Page 180: ...Index 170 SE505 Hardware Manual ...