Chapter 2
:
System Overview
24
SE505 Hardware Manual
➢
To configure the conveyor for Board Flow
1. Connect the board stop at the fixed conveyor rail as shown in Figure 24 for Left to Right
configuration which is the default configuration.
2. To change to use the Right to Left configuration, unscrew the two nuts on the board stop.
3. Mirror the board stop diagonally and replace the two nuts on the board stop.
Figure 23.
Board Stop Position
4. Route the cables along the opposite conveyor rail.
5. Connect the board stop to the fixed conveyor rail.
Figure 24.
Left to Right Board Flow Configuration
6. Calibrate the system in either of the following:
a.
Set the ConveyorOffsetX and ConveyorOffsetY values manually using the Configuration
Editor.
- or -
b.
Refer to “
Aligning the System”
section of the
SE505 Solder Paste Inspection Software User
Guide, Part Number: 8015918.
i
Note:
Set the
ConveyorRightToLeft
value using the Configuration Editor. The value “0’
indicates Left to Right configuration. The value ‘ 1’ indicates Right to Left configuration.
Left to Right configuration of board Stop
Board Stop
Board Stop
Panel Proximity Sensor (Entry)
Panel Proximity Sensor (Exit)
Movable Conveyor Rail
Fixed Conveyor
Rail