Chapter 3
:
Installation
38
SE505 Hardware Manual
➢
To adjust the system height (lowest height) configuration
1. Remove the side panels from the unit.
2. If not already configured for the lowest position, use a forklift to raise the unit 0.5–1 meter
(2–3 feet) off the floor.
3. Remove the two M8 screws that secure the plate and foot assembly to the frame.
4. Remove the leveling foot from the block.
5. Orient the block in the cylinder facing upward and the flat foot is down.
Figure 33.
Changing Leveling Foot
6. Reassemble the foot assembly onto the frame.
7. To adjust the leveling feet, loosen the locking nut with a wrench and then turn the
adjustment nut.
●
Turn the nut clockwise to raise the unit
●
Turn the nut counter-clockwise to lower the unit
Figure 34.
Leveling Foot
8. Use a level or machine height measurements to make sure that the system is level.
9. Manually slide a panel through the incoming and outgoing conveyor sections to make sure
that the SE505 conveyor rail is properly aligned. The panel should pass from the upstream
conveyor through the SE505 system and on to the downstream conveyor without any
resistance.
10. After adjusting the leveling feet, tighten the locking nuts.
Leveling foot block oriented
for standard configuration
Leveling foot block
oriented for lowest
conveyor position
Machine frame
Leveling foot
M8 Screws
Locking nut
Adjustment nut
Summary of Contents for SE505
Page 1: ...SE505 Hardware Manual ...
Page 6: ...Contents vi SE505 Hardware Manual ...
Page 10: ...x SE505 Hardware Manual ...
Page 72: ...Chapter 3 Installation 62 SE505 Hardware Manual ...
Page 168: ...Chapter 4 Replacing Components and Preventive Maintenance 158 SE505 Hardware Manual ...
Page 180: ...Index 170 SE505 Hardware Manual ...