Chapter 4
:
Replacing Components and Preventive Maintenance
102
SE505 Hardware Manual
5. The final position for the clamp blade is to have an optimal distance of 2.5–3 mm.
➢
To adjust the clamp blade into proper position
1. Loosen the clamp blade by turning the screw in a counter clockwise direction. This will
allow the clamp blade to slide forward/backward.
2. Lower down the blade holder into the clamping position. Slide the clamp blade until the gap
between the top guide and clamp blade is approximately 0.6–1.0 mm.
3. Tighten all the five blade mounting screws.
4. Test the clamper movement for up/down binding and interference.