69
Main Electrical Panel
Figure 51.
Replacing the Circuit Breaker
5. Reconnect the wires for outside line and system power.
a.
Insert a screwdriver to release the crimp-style connector.
b.
Insert the stripped portion of the wire into the connector.
c.
Remove the screwdriver to allow the connector to crimp the conductor.
d.
Pull the wire to ensure it is secured.
6. Place the power access cover back onto the panel and secure in place with four screws.
7. Turn the AC main circuit breaker to ON.
PE
PE
PE
N2
L2
PE
N1
L1
N
L
Power access cover
(Loosen) screws (x 4)
Strain relief nut
AC main
circuit
breaker
(CB1)
Pry open the crimping
connector using a
screwdriver and insert the
conductor.
Stripped wire
Screwdriver
NOTE: The SE505 does not comes with the power cord.
Back Electrical Panel
N (blue)
L (brown)
GND (yellow)
Power Cord
(AWG 14–16)