Chapter 4
:
Replacing Components and Preventive Maintenance
144
SE505 Hardware Manual
6. Replace the new encoder strip with the standard tool by pasting the strip onto the gantry.
Contact CyberOptics for the part number of the standard tooling kit.
7. Perform encoder read head adjustment after replacing the encoder strip. Refer to steps 6–10
on “
Adjusting the Encoder Read Head
” on page 145 for the procedures.
Standard Tooling kit
Encoder Strip