Electrical
6
‐
16
Troubleshooting a starter motor failure
Check:
1.
Fuses
(main, ignition, signaling) for continuity.
2.
Battery
for 12.8V or more
3.
Starter motor
Connect a jumper of equal size from the battery positive post to the starter motor.
Warning: If the size of jumper wire is too small the jumper could burn and
or cause injury.
4.
Starter relay
Connect the battery positive post to the yellow/blue
terminal (1) Connect the battery negative post to the
blue/black terminal (2) Connect the multimeter positive
lead to the red terminal (3) Connect the multimeter
negative lead to the black terminal (4). Check for
continuity.
5.
Main switch
for continuity
6.
Gear position switch
for continuity
7.
Brake light switch
for continuity
8.
Diode 1 for continuity
Connect the multimeter positive lead to the yellow/blue
terminal (1) Connect the multimeter negative lead to the
black/yellow terminal (2) or connect the multimeter
positive lead to the yellow/ blue terminal (1) Connect the
multimeter negative lead to the blue/white terminal (2)
Note: If the leads on the multimeter are reversed the results will be opposite.
9.
Wiring connections
Summary of Contents for Challenger 500
Page 1: ...SERVICE MANUAL Challenger 500 Challenger 700...
Page 50: ...500 UV Engine Specifications 2 10...
Page 51: ...500 UV Engine Specifications 2 1 1...
Page 52: ...500 UV Engine Specifications 2 12...
Page 53: ...500 UV Engine Specifications 2 13...
Page 209: ...Electrical 6 11 Ignition System Circuit Diagram 1 High tension coil 2 C D I 3 Magneto...
Page 213: ...Electrical 6 15 Electric Starting System...
Page 216: ...Electrical 6 18 Charging System...
Page 218: ...Electrical 6 20 Lighting System...
Page 219: ...Electrical 6 21 Signaling System...
Page 220: ...Electrical 6 22 Cooling System...
Page 221: ...Electrical 6 23 2WD 4WD Selecting System...
Page 244: ...MTD Products Inc Product Training and Education Department FORM NUMBER 769 10856 05 2015...