Display an HSS error code using its bit mask number
crayadm@smw>
xterrorcode 131279
Maximum error code (RS_NUM_ERR_CODE) is 447
code = 207, string = 'Node Voltage Fault'
3.4.27 Display Component State Information
Use the HSS
xtshow
command to identify the state of components. Commands are typed as xtshow --
option
_
name
.
Identify all nodes in the
disabled
state
crayadm@smw:~>
xtshow --disabled
L1s that are disabled...
Cages that are disabled...
r0s3: - ATHE| disabled [noflags|]
L0s that are disabled...
Nodes that are disabled...
Aries that are disabled...
AthenaISCBs that are disabled...
r0s3i0: - ATHE| disabled [noflags|]
AriesLcbs that are disabled...
The --disabled option in the preceding example shows all the disabled hardware components. For
more information, see the
xtshow(8)
man page.
3.4.28 Clear Component Flags
Use the
xtclear
command to clear system information for selected components. Type commands as
xtclear
--option_name
, where
option_name
is
alert
,
reserve
, or
warn
.
Clear all warnings in specified cabinet
For this example, clear all warnings in cabinet
c13-2
:
smw:~>
xtclear --warn r1
Alerts, reserves, and warnings must be cleared before a component can operate. Clearing an alert on a
component frees its state.
For more information, see the
xtclear(8)
man page.
3.4.29 Flash Management on Urika-GX
HSS is responsible for flashing all devices in the Urika
®
-GX system via an out-of-band (OOB) mechanism. This
can be achieved via the System Management Workstation (SMW)
rackfw
command, which is a flash tool. The
SMW flash tool is used to flash firmware of the following components:
System Management
S3016