node10: off
node11: on
node12: on
node13: on
node14: on
node15: on
node16: on
ok
[r0s0i0 /]#
pmnode
Display powerman style power status
Syntax:
pmnode [node|all]
Parameters:
node
Display status for a specified node, 1 through 16
all
Display status for all nodes
Example:
[r0s0i0 /]#
iscb pmnode 7
node07: on
ok
[r0s0i0 /]#
power
Power on/off/cycle/reset the specific node(s). If the node is already turned on, there will be
no action. When multiple nodes are given for power on/off/cycle operation, an interval value
is required. <CR> key to abort the power operation.
Syntax:
power <on|off|cycle|shutdown|reset> <node|all> [interval]
Parameters:
on
Turn on the specific nodes. If node is already turned on, there will be no
action.
off
Turn off the specific nodes. If node is already turned off, there will be no
action.
cycle
Turn off, then turn on, the specific nodes.
reset
Reset specific nodes. No interval time required for multiple nodes.
shutdown
OS shutdown of <all> or specified <nodes>. This command asserts the
ATX power control signal for 0.4 second to gracefully shutdown the node if
it is powered on. The specific node should be in proper ACPI mode w/ ATX
power control. If the node is in abnormal mode such as hung-up or PANIC,
this command may not work properly. Please check the node power status
once the command completes. No interval time is required for multiple
nodes.
node|all
Specific node 1 through 16
or
all
: all the nodes
or
System Monitoring
S3016
114