BMC reports CPU temperature to -60’C, the actual
temperature is 90-60 = 30’C. Default is 90.
danc [on|off]
dANC module power on|off.
debug [on|off]
Debug option.*
email [level [id
[server [user
[pass]]]]]
Event level, e-mail address, mail server/user/passwd of E-
Mail notification. Default community is public.*
fanspeed [low
normal high]
PWM duty of low, normal and high fan speed. Default is
60%, 90%, and 100%.
fastfan [on|off]
Dynamic Fast Fan Control by node’s health status. The
entire CFU will run at low, normal and high speed by one of
highest node’s temperature. If it is off, entire CFU will run at
normal active fan control mode. Default is off.
fantemp [normal
high]
Temperature of normal and high FAN speed. Default is
50'C and 65'C. For example, if the blade exceeds 65'C, the
CFU will run at high speed. temp [warning critical]. The
temperature region of warning and critical. Default is 85'C
and 90'C. For example, if the blade exceeds 85'C, the
blade health status is set to warning.
gpu [type
[slotmap]]
GPU/Co-proc type and PCI slot map. Type is one of auto,
m20xx, k10, k20, k40, k80 and phi.*
gputemp [temp]
The critical temperature of GPU/Co-proc expansion. For
nVidia M20XX and Kepler GPU, this value is will be used
for reference temperature for warning and critical
temperature region. For example, the nVidia GPU reports
temperature to 90’C, the iSCB determines the GPU health
status is ‘CRITICAL’. But for Intel MIC, the health status will
be determined by MIC SMC. Default is 90.
gw [gw [unitid]]
iSCB Gateway (10.10.1.254)*
hashpasswd [pass]
iSCB hashed password at
/etc/shadow
.
ip [ip [unitid]]
iSCB IP Address (10.10.1.11).*
ipmb [on|off]
The IPMB communication between iSCB and blade nodes.
If it is off, entire health monitoring and MPM capability will
not work. Default is on.*
ipsrc [static|
dhcp]
IP source from dhcp or static. ‘IDSW3-8 ON’overrides this
setting.*
loglevel [level]
Event logging level: critical, warning and info.
mac [mac address]
MAC address.
margin [low]
[high]
name [name]
Subrack alias name, 14 chars maximum.*
System Monitoring
S3016
119