39
2
Menu level
The menu level can be called by pressing the ‘
Menü a/A’
button.
The following menu items can be called (press ‘ ’ or ‘ ’ button in order to select the next or previous
menu item).
troubles
events
sensors
service
setup
run test
int. siren
ext. siren
alarm dialler
PC interf.
......
Troubles (see from page 59):
• Displays which sensors have troubles (or when the alarm base station’s batteries are empty,
for example)
• Possible troubles: Battery empty, contact open, sabotage
• Removal of the cause of the trouble on the sensor (or alarm base station, if its batteries are
empty)
Events (see page 63):
• Calls the last 1000 events with date, time and sensor name
• Events are, for example, arming/disarming, alarm signals etc.
Sensors (see from page 64):
The ‘sensors’ menu manages the individual sensors and consists of four sub-menus:
•
Add:
Register sensor and assign names
•
Delete:
Delete sensors
•
Names:
Modify the name of the sensor
•
Attributes:
Entry or modification of sensor attributes
(internal, external, closure group, PIR sensitivity)
Service (see page 71):
• Servicing the sensors, for example, replacing the batteries or adjusting the wiring without
triggering a sabotage alarm
• Sensor information is retained when the batteries are replaced.
Summary of Contents for FAZ 3000-PIR-2
Page 115: ...115...