71
d) Service (e.g., opening the casing and replacing the batteries)
This function is used for replacing the batteries (of the sensor, device or alarm base station) or
for modifying the wiring of the external NO/NC contacts connected to a door/window detector,
for example.
During the service neither the alarm nor the sabotage alarm are triggered (for example, opening
the casing of a sensor or device or the alarm base station immediately sets off an alarm!).
• You must be on the main level. The LCD should appear as on the right,
for example, with the time and the date.
• Briefly press the ‘
Menü a/A
’ button on the operating unit of the ‘FAZ
3000-Z’ alarm base station.
• Use the ‘ ’ and ‘ ’ buttons to select the ‘
service
service
service
service
service
’ menu. See the figure
on the right.
• Confirm your selection by briefly pressing the ‘
OK
’ button.
The first sensor that was registered with the alarm base station is
displayed.
• Use the ‘ ’ and ‘ ’ buttons to select the sensor that you wish to open
(in order to replace the batteries, for instance).
You can select other devices (signal transmitter, activation switch, alarm
dialler, PC interface and alarm base station) using the ‘ ’ button.
• Confirm your selection by briefly pressing the ‘
OK
’ button.
You can now open the casing of the selected sensor without setting
off a sabotage alarm, in order to replace the batteries, for example. No
data is lost and the sensor or the device does not need to be registered
again afterwards.
Once the new batteries have been inserted, the sensor’s LED briefly
blinks once. The radio connection to the alarm base station has been
established and checked.
Instead of replacing the batteries, you could also modify the wiring of
a door/window detector, in order to connect additional external NO/NC
contacts, for example.
• Once you have finished replacing the batteries or made changes to the
wiring, close the sensor’s casing again.
• The service is completed by pressing the ‘
OK
’ button. You are now in
the sensor list again. You can use the ‘ ’ and ‘ ’ buttons to select another
sensor (or select a device using the ‘ ’ button).
• You can exit the ‘service’ mode by pressing the ‘
C
’ button three times.
This returns you to the normal display mode (main level).
service
troubles
disarm
17:25 20.03
contact 1
livingr W1
contact 4
- service -
contact 4
bedr W1
disarm
17:47 20.03
contact 4
bedr W1
Summary of Contents for FAZ 3000-PIR-2