25
SI1
SI2
KL1
KL6
KL5
KL4
KL3
KL2
BU1
BU2
Öffnung
3. Alarm base station cabling
All the cable connections to the alarm base station are made from the back through the square
opening (see figure 13).
When connecting the cables, proceed according to the following sequence:
a) Connect the wired alarm lines and the sabotage line
b) Connect the DCF receiver (not supplied, must be ordered separately)
c) Connect the power supply cable (caution, do
not
connect the power supply to the supply
voltage yet!)
• Terminal strips ‘KL1’ to ‘KL6’
KL1
: Power supply for wired alarm lines (for example, PIR detector or similar).
12V=, max. 315mA (left: plus/+, right: minus/-)
KL2:
Difference line for sabotage
KL3:
Difference line for wired alarm line 1
KL4:
Difference line for wired alarm line 2
KL5:
Difference line for wired alarm line 3
KL6:
Difference line for wired alarm line 4
• ‘BU1’ connection for external power supply
Round socket for external power supply, 12V=, 500mA, ‘plus’ contact inside on the pin
• ‘BU2’ connection for external DCF receiver
Western socket for external DCF receiver
• Fuse SI1
Fuse for ‘FAZ 3000-Z’ power supply via BU1, 250V/500mA, slow-blow
• Fuse SI2
Fuse for KL1, 250V/315mA, slow-blow
Figure 13
opening