9. Rename output to RPM out
10. Go to I/O window and configure analog SCM AOUT1 as RPM out. Then configure output convert Low limit
(0 RPM ~ 0.00V output) and High output convert limit (2000 RPM ~ 10.00V output).
Speed governor output characteristics for Lo limit and Hi limit
setting above.
Speed governor output voltage in this case (when RPM1= 500
and RPM2=1800) is 9V when pressure is low and 2,5V when
pressure is high
11. Final PLC layout in DriveConfig