InteliDrive DCU Marine - 3.0.0 Global Guide
120
Setpoint group
Comms Settings
Related FW
3.0.0
Range [units]
[STANDARD, MODBUS]
Default value
STANDARD
Step
[-]
Comm object
24522
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Communication protocol selection.
STANDARD: InteliDrive (DriveConfig, InteliMonitor, Remote panel) communication protocol.
MODBUS: Modbus RTU protocol.
Note:
Detailed description of Modbus protocol include some examples, see in InteliGen Communication
guide.
RS232 Mode
Setpoint group
Comms Settings
Related FW
3.0.0
Range [units]
[19200, 38400, 57600, 115200] [bps]
Default value
38400
Step
[-]
Comm object
24341
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
The setpoint adjusts communication speed of the RS232 interface when
is set to
STANDARD.
Note:
If the controller is connected to IB-NT via the RS232 interface, set the speed to 57600 - the
supported communication speed.
RS232 TermCSpd