InteliDrive DCU Marine - 3.0.0 Global Guide
140
Setpoint group
Engine protect
Related FW
3.0.0
Range [units]
0 .. 60 [s]
Default value
0
Step
1
Comm object
10571
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Delay for Force block protection activation after binary input Force Block 3 is opened. Protection
deactivation is without delay. Protection is activated/deactivated independent on engine running or not
running state.
ForceBlockDel3
Setpoint group
Engine protect
Related FW
3.0.0
Range [units]
0 .. 200 [%]
Default value
110
Step
1% of Nominal RPM
Comm object
8263
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Threshold for engine overspeed protection.
Overspeed