InteliDrive DCU Marine - 3.0.0 Global Guide
172
Setpoint group
DetCon20
Related FW
3.0.0
Range [units]
0,0 .. 100,0 [%/s]
Default value
30,0 %/s
YES
Step
0,1 %/s
Comm object
10300
Related applications
All
Config level
Standard
Setpoint visibility
DetCon20 support configured
Description
Decrease ramp specifies rate at which is the timing reduction signal (analog output) decreased as soon as
knocking drops below the
IgnRedLimit
(ignition reduction limit).
DecreaseRamp
Setpoint group
DetCon20
Related FW
3.0.0
Range [units]
0 .. 255 [-]
Default value
10
YES
Step
1
Comm object
10299
Related applications
All
Config level
Standard
Setpoint visibility
DetCon20 support configured
Description
Ignition reduction limit is knocking value above which the engine is considered to be knocking. If the value is
exceeded, DetCon20 binary output ENGINE KNOCKING is activated and the values assigned to the timing
reduction are altered.
IgnRedLimit
Setpoint group
DetCon20
Related FW
3.0.0
Range [units]
0 .. 255 [-]
Default value
40
YES
Step
1
Comm object
10304
Related applications
All
Config level
Standard
Setpoint visibility
DetCon20 support configured
Description
Immediate stop limit is knocking value above which DetCon20 binary output TRIP is activated. This causes
engine to shut down if properly wired.
ImmStopLimit
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...