InteliDrive DCU Marine - 3.0.0 Global Guide
9
temperature (alternatively Aftertreatment values)
Indication:
LOC
(Local), Alarm (in AL or ECU list),
R
Remote data
connection active,
L
Access Lock
2
Analog 1 to Analog 4 , 4x single barograph
3
Analog 5 to Analog 8 , 4x single barograph (if they are configured)
4
Battery ID-DCU MARINE, bargraph, Engine Cylinders statistic
temperatures, Engine states timer
5
ID-DCU MARINE BI 1 to 7
6
ID-DCU MARINE BI 8 to 14
7
ID-DCU MARINE BO 1 to 7
8
ID-DCU MARINE BO 8 to 14
9
Statistics: Run hours, Number of starts, Service time
10
GPS speed (value is shared from other devices)
Following screens appears depend on configuration
Opt
Analog 1 to Analog 8, Name- value dimension, active alarm is
negative (1x IS-AIN8(TC) or Inteli AIN8(TC))
Opt
IS-BIN BI indication 1 to 8
Opt
IS-BIN BI indication 9 to 16
Opt
IS-BIN BO indication 1 to 8
Opt
ECU values I.
Opt
ECU values II.
Setpoints screens
correspond with Setpoint table above.
Alarm indication
Possible Alarm list and History record prefixes
Prefix
Meaning
Wrn
Warning
Sd
Shutdown
Cd
Cooldown
Bw
Broken wire
Fls
Sensor fail
Three state Alarm list indication
* Wrn Water temp
Active not accepted alarm
Wrn Water temp
Active accepted alarm
* Wrn Water temp
Inactive not accepted alarm
Inactive accepted alarm
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...