InteliDrive DCU Marine - 3.0.0 Global Guide
61
4.3.8 Connection of ID-DCU MARINE analog inputs
Standard connection of resistive sensors to ID-
DCU MARINE analog inputs AI1 to AI8. The COM
terminal must be always connected to the negative
power terminal.
Different sensors connection to ID-DCU MARINE.
AI configuration jumpers must be in corresponding
position and corresponding DriveConfig
configuration according to used sensor.
Analog input common terminal COM has to be
connected to ID minus Power supply terminal.
Mixed connection of ID-DCU MARINE analog
inputs:
AI2, AI7 - current sensor
AI1, AI5 - resistive sensor
AI3, AI8 - voltage input
AI6- thermocouple (voltage)
AI4 - Not used
Mixed connection of InteliDrive analog inputs:
AI1, AI2, AI5, AI6 - resistive sensor
AI3, AI7 - binary input
AI4, AI8 - three state input
Analog input common terminal COM has to be
connected to ID minus Power supply terminal.
To ensure a proper function use shielded cables, especially for length over >3 m.
4.3.9 ID-DCU MARINE Analog inputs hardware configuration
Configure Analog inputs AI1-AI8 connection by jumpers on PCB (remove cover).
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...