InteliDrive DCU Marine - 3.0.0 Global Guide
121
Setpoint group
Comms Settings
Related FW
3.0.0
Range [units]
[9600, 19200, 38400, 57600, 115200] [bps]
Default value
9600
Step
[-]
Comm object
24420
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
The setpoint adjusts communication speed of the RS485 interface when
is set to
MODBUS.
RS485 MBCSpd
Setpoint group
Comms Settings
Related FW
3.0.0
Range [units]
[STANDARD, MODBUS, ECU LINK]
Default value
STANDARD
Step
[-]
Comm object
24451
Related applications
All
Config level
Standard
Setpoint visibility
Always
Description
Communication protocol selection.
STANDARD: InteliDrive (DriveConfig, InteliMonitor, Remote panel) communication protocol.
MODBUS: Modbus RTU protocol.
ECU LINK: Connection to an electronic-controlled engine which uses non-J1939 ECU. The proper
ECU type must be also configured with GenConfig.
Note:
Detailed description of Modbus protocol include some examples, see in InteliGen Communication
guide.
RS485 Mode