InteliDrive DCU Marine - 3.0.0 Global Guide
64
Bargraph
100%
Bargraph ending value.
Function
Select from the list if function is required or leave free if input is a protection only.
Offset
Measured value offset.
Note:
Some configuration items (e.g. Protection) stay without change when Property - Sensor is changed to
None.
Sensors availability
Sensors available on ID-DCU MARINE
AI1 - AI4
Resolution
Sensor range
HW jumper
Pt1000/°C, Ni1000/°C,
Pt1000/°F, Ni1000/°F
Fix, not configurable
Resistance: 3-4
4-20 mA active,
±20 mA active (me only)
Adjustable -
see Hint
below.
For 20 mA input
Current: 1-2
0-250 Ω, 0-2400 Ω
For 250 or 2400 Ω
Input
Resistance: 3-4
Tristate
Resistance: 3-4
0 to 4 VDC
Adjustable
Voltage: 2-3
Sensors available on ID-DCU MARINE
AI5 - AI8
Resolution
Sensor range
HW jumper
Pt100/°C, Pt1000/°C, Ni100/°C, Ni1000/°C,
Pt100/°F, Pt1000/°F, Ni100/°F, Ni1000/°F
Fix, not configurable
Resistance: 3-4
Thermocpl J/°C, Th K/°C, Th/°C,
Thermocpl J/°F, Th. K/°F, ThL/°F
Fix, not configurable
Voltage: 2-3
4-20 mA active, ±20 mA active
Adjustable -
see Hint below.
For 20 mA input
Current: 1-2
0-250 Ω, 0-2400 Ω
For 250 or 2400 Ω
input
Resistance: 3-4
±1 V, 0-100 mV
For 1V or 100mV
Voltage: 2-3
Tristate
Resistance: 3-4
0 to 5 VDC
Adjustable
Voltage: 2-3
Configuration examples
Conversion from 4-20 mA to 6.0 Bar Oil pressure sensor (Wrn+Sd protection and Oil press function)
Summary of Contents for InteliDrive DCU Marine
Page 29: ...InteliDrive DCU Marine 3 0 0 Global Guide 29 Protection delay and blocking ...
Page 51: ...InteliDrive DCU Marine 3 0 0 Global Guide 51 4 2 2 Electronic engine without redundancy line ...
Page 255: ...InteliDrive DCU Marine 3 0 0 Global Guide 255 Analog inputs from J1939 configuration ...
Page 265: ...InteliDrive DCU Marine 3 0 0 Global Guide 265 Engine Values ...
Page 285: ...InteliDrive DCU Marine 3 0 0 Global Guide 285 6 back to Appendix 6 back to Table of contents ...