InteliDrive DCU Marine - 3.0.0 Global Guide
151
Setpoint visibility
Always
Description
Requested RPM ramp – see drawing.
Value
Description
Dimension
InteliMonitor
ID-DCU
MARINE
display
Loadsharing group
RQSP aver
Average of Requested RPM values
calculated from all controllers participating
in loadsharing
%
YES
YES
RQSP
ramp
RQSP aver value after ramp specified by
Loadsharing: RQSP Ramp setpoint
%
YES
YES
ThrottlePos
Throttle position
%
YES
YES
Engine values group
Speed
Request
Speed request
%
YES
NO
Image 8.1 Load sharing block diagram
Note:
The maximal ThrottlePos difference between parallel operating engines (due to Load sharing
function) is 1,5%.
ThrottlePos output (request to EMS) is switched to be equal to the Engine Values: Speed request after
other engines clutches are disconnected (no load sharing, only one engine powers the shaft).