The following figure shows the DC power supply with lead wires.
Figure 223: DC Power Supply with Lead Wires
Ground lead wire
3
Negative (
–
) lead wire
1
—
—
Positive (+) lead wire
2
Step 7
Insert the exposed wire of one of the ground wire into the terminal block plug. Ensure that you cannot see any wire lead.
Only wires with insulation should extend from the terminal block.
Do not overtorque the terminal block plug captive screws. The recommended maximum torque is from 0.5
Nm (4.425 lbf in.) to 0.6 Nm (5.310 lbf in.).
Caution
Cisco ASR 1000 Series Router Hardware Installation Guide
456
Cisco ASR 1001 Router Overview and Installation
Installing DC Input Power on the Cisco ASR 1001 Router