Power supply tabs
8
Negative (-) lead
3
+27 VDC INPUT label
9
Ground (GND) lead
4
—
—
Power supply LEDs
5
The following table shows the definitions of the Cisco ASR 1002-X 24 VDC power supply LEDs.
Table 73: Cisco ASR 1002-X 24 VDC Power Supply LEDs
Description
Color
LED
LED Label
When the LED is off, it signals
that the +24 VDC output
voltage is within the normal
operating range. Output voltage
between the minimum limit and
maximum limit will not create
an output fail alarm, but output
voltages below the minimum
limit or above the maximum
limit will create an Output Fail
alarm.
When you turn the power
supply on, LED turns red for
two to three seconds to test the
LED operation before going off.
Red
Power supply activity
OUTPUT FAIL
The LED turns green to signal
that voltage is > or = to 20 VDC
at turn-on and the voltage
reduces to 19.0VDC (+/- 0.5 V
tolerance).
Green
A bicolor LED indicates the
presence of input voltage
INPUT OK
The LED turns to amber when
the input voltage is active and
is reduced to 16.0 VDC and
indicates that a voltage on the
terminal block is still present.
The LED remains amber and is
active until around 10 V. The
LED should be OFF below 15.8
VDC.
Amber
The LED turns to green when
all fans are operational.
Green
A bicolor LED indicates the
power supply fan status
FAN OK
The LED turns to red when a
fan failure is detected.
Red
Cisco ASR 1000 Series Router Hardware Installation Guide
328
Cisco ASR 1002-X Router Overview and Installation
Power Supplies in the Cisco ASR 1002-X Router
Summary of Contents for ASR 1001
Page 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Page 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Page 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Page 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...