Table 75: +24 VDC Output Voltage Alarm Threshold Ranges
Maximum
Minimum
Output
12.8-13.8 V
10.0-11.2 V
12 V
None
2.6
–
3.0 V
3.3 V
•
Temperature
—
If a fan fails, the power supply meets the functional requirements specified in above
table. The calculated MTBF does not apply above 55°C with less than two fans. However, all the
component stress remains within the manufacturer
’
s specified rating.
•
Thermal shutdown
—
The +24 VDC power supply shuts down to protect its components due to excessive
internal temperature. The +24 VDC power supply then automatically restarts after the internal temperature
returns to a safe operating level.
Power Cords Supported by the Cisco ASR 1002-X Router
The following table lists the power cords that are supported by the Cisco ASR 1002-X Router.
Table 76: Power Cords Supported by the Cisco ASR 1002-X Router
Description
Power Cord Item Number
Power Cord, 110 V, Right Angle
CAB-AC-RA
Plug, Power Cord, Australia, 10 A, Right Angle
CAB-ACA-RA
Power Cord, Brazil, Right Angle, 10 A
CAB-ACB10A-RA
Power Cord, Brazil, Right Angle, 16 A
CAB-ACB16A-RA
Power Cord, China, Right Angle
CAB-ACC-RA
Power Cord, Europe, Right Angle
CAB-ACE-RA
Power Cord, Italy, Right Angle
CAB-ACI-RA
Power Cord, Argentina, Right Angle
CAB-ACR-RA
Power Cord, Switzerland, Right Angle
CAB-ACS-RA
Power Cord, UK, Right Angle
CAB-ACU-RA
Power Cord, India, Right Angle
CAB-IND-RA
Power Cord, Japan, Right Angle
CAB-JPN-RA
Cisco ASR 1000 Series Router Hardware Installation Guide
330
Cisco ASR 1002-X Router Overview and Installation
Power Supplies in the Cisco ASR 1002-X Router
Summary of Contents for ASR 1001
Page 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Page 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Page 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Page 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...