You can mount the chassis in a19-inch wide (standard), 4-post equipment rack or two-post, using the rack-mount
brackets in the accessory kit. The Cisco ASR 1013 Router supports 6 SIPs and provides superslots (more
height and power) for the Cisco ASR1000-RP2s and Cisco ASR1000-ESP cards.
The Cisco ASR 1013 Router usually ships fully loaded. However, you can remove components from the
chassis to make the chassis lighter for your rack installation.
Note
General Rack Installation Guidelines
When planning your rack installation, consider the following guidelines:
•
T
he Cisco ASR 1013 Router overall height is 22.75 inches (57.8 cm). You can install three Cisco ASR
1013 routers in a 42RU equipment rack; but must allow at least one to two inches (2.54 cm to 5.08 cm)
of vertical clearance between the router and any equipment above or below it. Measure the proposed
rack location before mounting the chassis in the rack.
•
Before using a particular rack, check for obstructions (such as a power strip) that could impair rack-mount
installation. If a power strip does impair a rack-mount installation, remove the power strip before installing
the chassis, and then replace it after the chassis is installed.
•
Allow sufficient clearance around the rack for maintenance. If the rack is mobile, you can push it back
near a wall or cabinet for normal operation and pull it out for maintenance (installing or moving cards,
connecting cables, or replacing or upgrading components). Otherwise, allow 19 inches (48.3 cm) of
clearance to remove field-replaceable units.
•
Maintain a minimum clearance of 3 inches (7.62 cm) on the front, top, and sides of the chassis for the
cooling air inlet and exhaust ports, respectively. Avoid placing the chassis in an overly congested rack
or directly next to another equipment rack; otherwise, the heated exhaust air from other equipment can
enter the inlet air vents and cause an overtemperature condition inside the router.
To prevent chassis overheating, never install a Cisco ASR 1013 Router in an enclosed room that is not
properly ventilated or air conditioned.
Caution
•
Always install heavier equipment in the lower half of a rack to maintain a low center of gravity to prevent
the rack from falling over.
•
Install and use the cable-management brackets included with the Cisco ASR 1013 Router to keep cables
organized and out of the way of the cards and processors. Ensure that cables from other equipment
already installed in the rack do not impair access to the cards or require you to disconnect cables
unnecessarily to perform equipment maintenance or upgrades.
•
Install rack stabilizers (if available) before you mount the chassis.
•
Provide an adequate chassis ground (earth) connection for your chassis.
In addition to the preceding guidelines, review the precautions for avoiding excessive temperature conditions
in the
.
The following table provides the Cisco ASR 1013 Router dimensions and weight information.
Cisco ASR 1000 Series Router Hardware Installation Guide
372
Cisco ASR 1013 Router Overview and Installation
General Rack Installation Guidelines
Summary of Contents for ASR 1001
Page 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Page 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Page 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Page 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...